Moldable6x6: for heating molds

Mouldeable 6x6

Technical Data

Profile 6 x 6 mm
Maximum length straight 1550mm
Carrier material Stainless steel
Cartridge surface temperature Max. 750ºC
Voltage 230v
Minimum bending radius R20 (inside)
R23 (neutral phase)
Connection Rigid nickel pin diameter 2.5mm
Insulation resistance (cold) 5 mΩ at 500V
Leakage current (cold) 0,1 mA at 253V
High voltage stability (cold) Min. 1250V
Inactive zone length Min. 30mm
Wattage tolerance (cold) +-10%
Cross-section tolerance (cold) 6.1mm +/-0.15%
Length tolerance +/-1.5% (min 1 mm)
Max. Watt density of heating element surface 10 w/cm2

Measures

Length Watts 230v
AISSI 321
350 550
400 650
450 750
500 800
550 900
600 1000
650 1100
700 1200
750 1300
800 1350
850 1450
900 1650
950 1650
Length Watts 230v
AISSI 321
1000 1750
1050 1850
1100 1950
1150 2050
1200 2100
1250 2200
1300 2300
1350 2400
1400 2500
1450 2600
1500 2700
1550 2800
   

 